Potentiometric Measurement Of Polymer-Membrane Electrodes Based On Lanthanum

Saefurohman, Asep and Buchari1, and Noviandri, Indra and Syoni, Potentiometric Measurement Of Polymer-Membrane Electrodes Based On Lanthanum.

[img]
Pra Tinjau
Teks
AIP Index Scopus-Potentiometric Measurement Of Polymer-Membrane Electrodes Based On Lanthanum.pdf

Download (174kB) | Pra Tinjau
[img]
Pra Tinjau
Teks
Potentiometric Selectivity.pdf

Download (1MB) | Pra Tinjau

Abstrak

Quantitative analysis of rare earth elements which are considered as the standard method that has a high accuracy, and detection limits achieved by the order of ppm is inductively coupled plasma atomic emission spectroscopy (ICPAES). But these tools are expensive and valuable analysis of the high cost of implementation. In this study be made and characterized selective electrode for the determination of rare earth ions is potentiometric. Membrane manufacturing techniques studied is based on immersion (liquid impregnated membrane) in PTFE 0.5 pore size. As ionophores to be used tri butyl phosphate (TBP) and bis(2-etylhexyl) hydrogen phosphate. There is no report previously that TBP used as ionophore in polymeric membrane based lanthanum. Some parameters that affect the performance of membrane electrode such as membrane composition, membrane thickness, and types of membrane materials studied in this research. Manufacturing of Ion Selective Electrodes (ISE) Lanthanum (La) by means of impregnation La membrane in TBP in kerosene solution has been done and showed performance for ISE-La. FTIR spectrum results for PTFE 0.5 pore size which impregnated in TBP and PTFE blank showed difference of spectra in the top 1257 cm-1, 1031 cm-1 and 794.7 cm-1 for P=O stretching and stretching POC from group -OP =O. The result showed shift wave number for P =O stretching of the cluster (-OP=O) in PTFE-TBP mixture that is at the peak of 1230 cm-1 indicated that no interaction bond between hydroxyl group of molecules with molecular clusters fosforil of TBP or R3P = O. The membrane had stable responses in pH range between 1 and 9. Good responses were obtained using 10-3 M La(III) internal solution, which produced relatively high potential. ISE-La showed relatively good performances. The electrode had a response time of 29±4.5 second and could be use for 50 days. The linear range was between 10-5 and 10-1 M.

Tipe Item/Data: Artikel
Kata Kunci (keywords): Lanthanide, Potentiometry, ESI-La, TBP, D2EHP
User Penyetor: S.IPI Tsulatsiah Andi
Tanggal Disetorkan: 27 Mar 2023 02:58
Perubahan Terakhir: 20 Apr 2023 07:44
URI: http://repository.uinbanten.ac.id/id/eprint/11700

Actions (login required)

Lihat Item Lihat Item

      is powered by EPrints 3 which is developed by the Islamic Institutional Repository UIN Sultan Maulana Hasanuddin Banten. More information and software credits.